Issue
=====
While listing datacenters associated with a zone, only zone Id validation is required.
There is no need to have additional checks like zone is a legacy zone or not.
Fix
===
Removed unnecessary checks over zone ID and just checking if zone with specified ID exists or not.
Signed-off-by: Sateesh Chodapuneedi <sateesh.chodapuneedi@accelerite.com>
(cherry picked from commit 0ef1c17541)
Signed-off-by: Rohit Yadav <rohit.yadav@shapeblue.com>
Summary: CLOUDSTACK-8921
snapshot_store_ref table should store actual size of back snapshot in secondary storage
Calling SR scan to make sure size is updated correctly
(cherry picked from commit 4e4b67cd96)
Signed-off-by: Rohit Yadav <rohit.yadav@shapeblue.com>
with XenServer & Local SR (Db_exn.Uniqueness_constraint_violation)
removed the host uuid from SR label so that any host which has access to
the SR(all the hosts in the same pool) can reuse the same SR
(cherry picked from commit 1aa6a72bc7)
Signed-off-by: Rohit Yadav <rohit.yadav@shapeblue.com>
as that snapshot will never be going to use again and also it will fill up primary storage
(cherry picked from commit 336df84f17)
Signed-off-by: Rohit Yadav <rohit.yadav@shapeblue.com>
Updated hardcoded value with max data volumes limit from hypervisor capabilities.
(cherry picked from commit 93f5b6e8a3)
Signed-off-by: Rohit Yadav <rohit.yadav@shapeblue.com>
Libvirt / Qemu (KVM) does not collect statistics about these either.
On some systems it might even yield a 'internal error' from libvirt
when attempting to gather block statistics from such devices.
For example Ubuntu 16.04 (Xenial) has a issue with this.
Skip them when looping through all devices.
Signed-off-by: Wido den Hollander <wido@widodh.nl>
The 'force' option provided with the stopVirtualMachine API command is
often assumed to be a hard shutdown sent to the hypervisor, when in fact
it is for CloudStacks' internal use. CloudStack should be able to send
the 'hard' power-off request to the hosts.
When forced parameter on the stopVM API is true, power off (hard shutdown)
a VM. This uses initial changes from #1635 to pass the forced parameter
to hypervisor plugin via the StopCommand, and fixes force stop (poweroff)
handling for KVM, VMware and XenServer.
Signed-off-by: Rohit Yadav <rohit.yadav@shapeblue.com>
* 4.9:
Do not set gateway to 0.0.0.0 for windows clients
CLOUDSTACK-9904: Fix log4j to have @AGENTLOG@ replaced
ignore bogus default gateway when a shared network is secondary the default gateway gets overwritten by a bogus one dnsmasq does the right thing and replaces it with its own default which is not good for us so check for '0.0.0.0'
Activate NioTest following changes in CLOUDSTACK-9348 PR #1549
CLOUDSTACK-9828: GetDomRVersionCommand fails to get the correct version as output Fix tries to return the output as a single command, instead of appending output from two commands
CLOUDSTACK-3223 Exception observed while creating CPVM in VMware Setup with DVS
CLOUDSTACK-9787: Fix wrong return value in NetUtils.isNetworkAWithinNetworkB
with XenServer & Local SR (Db_exn.Uniqueness_constraint_violation)
removed the host uuid from SR label so that any host which has access to
the SR(all the hosts in the same pool) can reuse the same SR
1. Removed XenServerGuestOsMemoryMap from CitrixHelper.java
This java file was holding a static in memory map named XenServerGuestOsMemoryMap. This was the source for xenserver dynamic memory values(max and min). These values were moved to guest_os_details table.
2. DAO layer was modified to access these values.
3. VirtualMachineTo object was modified to populate the dynamic memory values.
4. addGuestOs and UpdateGuestOS api has been modified to update memory values.
This fixes log4j xml to have @AGENTLOG@ replaced with values defined
in build/replace.properties.
Signed-off-by: Rohit Yadav <rohit.yadav@shapeblue.com>
Test scenarios:
- Enable cluster HA after VR is created. Now stop and start VR and check its restart priority, should be High.
- Enable cluster HA before VR is created. Now create some VM and verify that VR created must have High restart priority.
CLOUDSTACK-9720: [VMware] template_spool_ref table is not getting updated with correct template physical size in template_size column.Updated the template_spool_ref table with the correct template (VMware - OVA file) size.
* pr/1880:
CLOUDSTACK-9720: [VMware] template_spool_ref table is not getting updated with correct template physical size in template_size column.
Signed-off-by: Rajani Karuturi <rajani.karuturi@accelerite.com>
Summary: CLOUDSTACK-8921
snapshot_store_ref table should store actual size of back snapshot in secondary storage
Calling SR scan to make sure size is updated correctly