This PR slows down the console paste text function in the console ever so slightly, adding 25ms between each character. It was found that when large text is pasted, say an SSH key or something over 100 characters, it would stop somewhere in the 100-200 character range, and if the last character was capitalized it would be stuck with left shift held down.
In debugging, I ran noVNC locally with websockify against a Qemu VNC and took the whole console proxy out of the equation and was still able to reproduce it. I traced the websocket packets and we were clearly firing off all of the keypresses just fine, but the ones on the end were getting dropped VNC server side. It seems we are overloading a keyboard buffer, or something along those lines when we send all of the keypress messages at once. It was also observed that we were able to send off all of the messages via websocket in just a few ms but the typing on the guest side took a few seconds, so there is some buffering and processing going on and I think we are just hitting some limit in this.
This sendText function doesn't seem to exist in upstream noVNC, so just patching it here seems reasonable. I suspect we added this for feature parity with whatever noVNC replaced.
In testing it is now much more reliable in sending a few paragraphs of text, and not visibly slower than before, but obviously still too slow to do anything really big with it. It isn't really the goal to be able to paste full documents.
Co-authored-by: Marcus Sorensen <mls@apple.com>
* Better hover label and message for generate API/secret keys form
* Added a message to select network during instance deployment
* Removed project icon in dashboard listing
* Disable network operations for the user who does not have permission
* UI allignments
* added document help for sticky policy secion under load balancer
* Added tooltips and some form layout changes
* donot display options to configure when stickypolicy is none
* Network selection message allignment
* Fixed the grid view to be uniform in infra summary page
Fixes#7442
With d74f64a2e1 key for the host header was changed to lowercase which is causing host be null while processing upload in SSVM
Signed-off-by: Abhishek Kumar <abhishek.mrt22@gmail.com>
Co-authored-by: João Jandre <48719461+JoaoJandre@users.noreply.github.com>
This PR adds name in updateProject API to allow renaming 'name' field with description from both API and UI level.
Fixes: #7107
Signed-off-by: Abhishek Kumar <abhishek.mrt22@gmail.com>
Co-authored-by: Rahul Agarwal <rahul.agarwal@shapeblue.com>
Co-authored-by: Abhishek Kumar <abhishek.mrt22@gmail.com>
This PR allows admin to filter resources by state for systemvms, router & storagepool. This is part of #7366 .
Co-authored-by: Abhishek Kumar <abhishek.mrt22@gmail.com>
Co-authored-by: Rohit Yadav <rohit.yadav@shapeblue.com>
* UI changes for management server comments
* Added support for mgmt server comments in annotations framework
* Added test for mgmt server annotation
* changed annotation to be unique for mgmt server test
Fixes#7389
Fixes listing of service offerings for VM scale when the current offering has `disk_offering_strictness=true`
Signed-off-by: Abhishek Kumar <abhishek.mrt22@gmail.com>
This PR fixes an issue observed on multiple zones and direct download templates on KVM, in which a template gets multiple records on the template_store_ref table. When this happens, the template cannot be used as direct download. In case of a system VM template using direct download, system VM deployments fail
This PR fixes#7362 and also other search criteria to use the name as an exact search where keyword is also there.
Made UI changes for roles search to make use of keyword instead of name.
This fix ensures when datastore cluster in VMware is added as a primary storage pool in CloudStack then all the child datastores (which already exists in CS) should be in Up state.
For example:
1. Datastore Cluster DS has two child datastores A and B in vCenter. (B is already added as a storage pool in CloudStack)
2. Now try to add datastore cluster DS into CloudStack as a primary storage pool
3. CloudStack tries to add child datastores A and B in CloudStack, since B is already there in CloudStack, it will reuse the existing storagepool entry and will keep under parent Storage pool DS.
During Step 3 we are now checking if B is Up state or not.
Currently create network form takes account name (manual entry) as one of the parameters. During network creation we check if the given account name is under selected domain.
Here with this PR we are listing accounts under the selected domain.
* ui: show only Advance zones for vmautoscale form
Fixes#7409
Signed-off-by: Abhishek Kumar <abhishek.mrt22@gmail.com>
* fix non-securitygroupenabled zones
Signed-off-by: Abhishek Kumar <abhishek.mrt22@gmail.com>
---------
Signed-off-by: Abhishek Kumar <abhishek.mrt22@gmail.com>