* 4.7:
Fix Sync of template.properties in Swift
Configure rVPC for router.redundant.vrrp.interval advert_int setting
Have rVPCs use the router.redundant.vrrp.interval setting
Resolve conflict as forceencap is already in master
Split the cidr lists so we won't hit the iptables-resture limits
Check the existence of 'forceencap' parameter before use
Do not load previous firewall rules as we replace everyhing anyway
Wait for dnsmasq to finish restart
Remove duplicate spaces, and thus duplicate rules.
Restore iptables at once using iptables-restore instead of calling iptables numerous times
Add iptables copnversion script.
It defaults to 1, which is hardcoded in the template:
./cosmic/cosmic-core/systemvm/patches/debian/config/opt/cloud/templates/keepalived.conf.templ
As non-VPC redundant routers use this setting, I think it makes sense to use it for rVPCs as well.
We also need a change to pickup the cmd_line parameter and use it in the Python code that configures the router.
* 4.7:
CLOUDSTACK-9287 - Improve test by checking if pvt gw is removed and fix typos
Handle private gateways more reliably
CLOUDSTACK-9287 - Fix RVR public interface
CLOUDSTACK-9287 - Add integration test to cover the private gateway related changes
CLOUDSTACK-9287 - Refactor the interface state configuration
CLOUDSTACK-9287 - Check if the nic profile has already been removed from a certain router
CLOUDSTACK-9287 - Bring up the private gw interface on state change to master
CLOUDSTACK-9287 - Make sure private gw interface is not used for default gw
CLOUDSTACK-9287 - Add integration test to cover the private gw interface/mac address issues
CLOUDSTACK-9287 - Put private gateway interface down on backup router
CLOUDSTACK-9287 - Generate new mac address if router is redundant and nic profile exists
Add private gateway IP to router initialization config
apply static routes on change to master state
Handle private gateways more reliablyWhen initialising a VPC router we need to know which IP/device corresponds to a private gateway. This is to solve a problem when stop/starting a VPC router (which gets the private gateway config as a guest network and as a result breaks the functionality). You read it right, the private gateway is sent as type=guest after reboot and type=public initially.
Before this change, you could add a private gw to a running router but you couldn't restart it (it would mix up the tiers). Now the private gateway is detected properly and it works just fine.
Booting without private gateway:
```
root@r-167-VM:~# cat /etc/cloudstack/cmdline.json
{
"config": {
"baremetalnotificationapikey": "V2l1u3wKJVan01h8kq63-5Y5Ia3VLEW1v_Z6i-31QIRJXlt5vkqaqf6DVcdK0jP3u79SW6X9pqJSLSwQP2c2Rw",
"baremetalnotificationsecuritykey": "OXI16srCrxFBi-xOtEwcYqwLlMfSFTlTg66YHtXBBqR7HNN1us3HP5zWOKxfVmz4a3C1kUNLPrUH13gNmZlu4w",
"disable_rp_filter": "true",
"dns1": "8.8.8.8",
"domain": "cs2cloud",
"eth0ip": "169.254.0.42",
"eth0mask": "255.255.0.0",
"host": "192.168.22.61",
"name": "r-167-VM",
"port": "8080",
"privategateway": "None",
"redundant_router": "false",
"template": "domP",
"type": "vpcrouter",
"vpccidr": "10.0.0.0/24"
},
"id": "cmdline"
```
Booting with private gateway:
```
root@r-167-VM:~# cat /etc/cloudstack/cmdline.json
{
"config": {
"baremetalnotificationapikey": "V2l1u3wKJVan01h8kq63-5Y5Ia3VLEW1v_Z6i-31QIRJXlt5vkqaqf6DVcdK0jP3u79SW6X9pqJSLSwQP2c2Rw",
"baremetalnotificationsecuritykey": "OXI16srCrxFBi-xOtEwcYqwLlMfSFTlTg66YHtXBBqR7HNN1us3HP5zWOKxfVmz4a3C1kUNLPrUH13gNmZlu4w",
"disable_rp_filter": "true",
"dns1": "8.8.8.8",
"domain": "cs2cloud",
"eth0ip": "169.254.2.227",
"eth0mask": "255.255.0.0",
"host": "192.168.22.61",
"name": "r-167-VM",
"port": "8080",
"privategateway": "10.201.10.1",
"redundant_router": "false",
"template": "domP",
"type": "vpcrouter",
"vpccidr": "10.0.0.0/24"
},
"id": "cmdline"
```
And:
```
cat cmdline
vpccidr=10.0.0.0/24 domain=cs2cloud dns1=8.8.8.8 privategateway=10.201.10.1 template=domP name=r-167-VM eth0ip=169.254.2.227 eth0mask=255.255.0.0 type=vpcrouter disable_rp_filter=true baremetalnotificationsecuritykey=OXI16srCrxFBi-xOtEwcYqwLlMfSFTlTg66YHtXBBqR7HNN1us3HP5zWOKxfVmz4a3C1kUNLPrUH13gNmZlu4w baremetalnotificationapikey=V2l1u3wKJVan01h8kq63-5Y5Ia3VLEW1v_Z6i-31QIRJXlt5vkqaqf6DVcdK0jP3u79SW6X9pqJSLSwQP2c2Rw host=192.168.22.61 port=8080
```
Logs:
```
2016-02-24 20:08:45,723 DEBUG [c.c.n.r.VpcVirtualNetworkApplianceManagerImpl] (Work-Job-Executor-4:ctx-458d4c52 job-1402/job-1403 ctx-d5355fca) (logid:5772906c) Set privategateway field in cmd_line.json to 10.201.10.1
```
* pr/1474:
Handle private gateways more reliably
Add private gateway IP to router initialization config
Signed-off-by: Will Stevens <williamstevens@gmail.com>
- In case of redundant VPCs, the ACL items are revoked in the first iteration. Since the econd iteration
is needed in order to remove the private network, we have to check if the nic profile is gone before trying
to revoke the ACL items again, which would throw a NPE.
- Some variable extraction in order to ease debugging.
* 4.7:
CLOUDSTACK-9254: Make longer names display pretty
CLOUDSTACK-9245 - Deletes ACL items when destroying the VPC or deleting the ACL itself
CLOUDSTACK-9245 - Formatting NetworkACLServiceImpl class
CLOUDSTACK-9245 - Formatting VpcManagerImpl class
CLOUDSTACK-9245 - Formatting NetworkACLManagerImpl class
More VR performance!
* 4.7:
CLOUDSTACK-9237: Create LB Healthcheck issues - button alignment and error message goes outside the window
CLOUDSTACK-9235: Autoscale button is missing in VPC
CLOUDSTACK-9229: Autoscale policy creation failing in VPC due to zoneid missing in createAutoScaleVmProfile
* 4.7:
CLOUDSTACK-9222 Prevent cloud.log.1 filling up the disk
Add integration test for restartVPC with cleanup, and Private Gateway enabled.
Nullpointer Exception in NicProfileHelperImpl
NicProfileHelperImpl NullpointerException when ipVO is nullWhen a VPC has a private gateway, and one would like to restart the VPC with **cleanup** it would fail.
This PR adds a NullPointer check and verifies it with an integration test.
```
test_01_vpc_privategw_acl (integration.smoke.test_privategw_acl.TestPrivateGwACL) ... === TestName: test_01_vpc_privategw_acl | Status : SUCCESS ===
ok
test_02_vpc_privategw_static_routes (integration.smoke.test_privategw_acl.TestPrivateGwACL) ... === TestName: test_02_vpc_privategw_static_routes | Status : SUCCESS ===
ok
test_03_vpc_privategw_restart_vpc_cleanup (integration.smoke.test_privategw_acl.TestPrivateGwACL) ... === TestName: test_03_vpc_privategw_restart_vpc_cleanup | Status : SUCCESS ===
ok
test_04_rvpc_privategw_static_routes (integration.smoke.test_privategw_acl.TestPrivateGwACL) ... === TestName: test_04_rvpc_privategw_static_routes | Status : SUCCESS ===
ok
----------------------------------------------------------------------
Ran 4 tests in 2945.055s
OK
```
* pr/1328:
Add integration test for restartVPC with cleanup, and Private Gateway enabled.
Nullpointer Exception in NicProfileHelperImpl
Signed-off-by: Remi Bergsma <github@remi.nl>
* 4.7:
Fix unable to setup more than one Site2Site VPN Connection
FIX S2S VPN rVPC: Check only redundant routers in state MASTER
PEP8 of integration/smoke/test_vpc_vpn
Add S2S VPN test for Redundant VPC
Make integration/smoke/test_vpc_vpn Hypervisor independant
FIX VPN: non-working ipsec commands
[UI] MADNESS
[DB] Add force_encap field to s2s_customer_gateway table
[ROUTER] Add forceencaps field to python router ipsec config method
[TEST] unittest needs rework
[MARVIN] Add forceencap field to VpnCustomerGateway class in marvin base
[CORE] Add Force UDP Encapsulation option to Site2Site VPN
CLOUDSTACK-9186: Root admin cannot see VPC created by Domain admin user
CLOUDSTACK-9192: UpdateVpnCustomerGateway is failing
CLOUDSTACK-6485 prevent ip asignment of private gw iface
CLOUDSTACK-9204 Do not error when staticroute is already gone
make both check lines consistent
CLOUDSTACK-9181 Prevent syntax error in checkrouter.sh
CLOUDSTACK-9202 Bump ssh timeout
[4.7] FIX Site2SiteVPN on redundant VPCThis PR:
- fixes the inability to setup more than one Site2Site VPN connection from a VPC
- fixes starting of Site2Site VPN on redundant VPC
- fixes Site2Site VPN state checking on redundant VPC
- improves the vpc_vpn test to allow multple hypervisors
- adds an integration test for Site2Site VPN on redundant VPC
Tested it on 4.7 single Xen server zone:
command:
```
nosetests --with-marvin --marvin-config=/data/shared/marvin/mct-zone1-xen1.cfg -a tags=advanced,required_hardware=true /tmp/test_vpc_vpn.py
```
results:
```
Test Site 2 Site VPN Across redundant VPCs ... === TestName: test_01_redundant_vpc_site2site_vpn | Status : SUCCESS ===
ok
Test Remote Access VPN in VPC ... === TestName: test_01_vpc_remote_access_vpn | Status : SUCCESS ===
ok
Test Site 2 Site VPN Across VPCs ... === TestName: test_01_vpc_site2site_vpn | Status : SUCCESS ===
ok
----------------------------------------------------------------------
Ran 3 tests in 1490.076s
OK
```
also performed numerous manual inspections of state of VPN connections and connectivity between VPC's
* pr/1276:
Fix unable to setup more than one Site2Site VPN Connection
FIX S2S VPN rVPC: Check only redundant routers in state MASTER
PEP8 of integration/smoke/test_vpc_vpn
Add S2S VPN test for Redundant VPC
Make integration/smoke/test_vpc_vpn Hypervisor independant
FIX VPN: non-working ipsec commands
Signed-off-by: Remi Bergsma <github@remi.nl>
CLOUDSTACK-6485 prevent ip asignment of private gw ifacePrevent ipaddress asignment of gateway to gateway-interface on vpc router by setting vpcid to null in network. This was fixed in 4.4 by 1f209ff226, reimplemented for 4.7
* pr/1299:
CLOUDSTACK-6485 prevent ip asignment of private gw iface
Signed-off-by: Remi Bergsma <github@remi.nl>
Prevent ipaddress asignment of gateway to gateway-interface on vpc router by setting vpcid to null in network
Was fixed in 4.4 by 1f209ff226
Reimplemented for 4.7
CLOUDSTACK-4374 - As a Developer I want to have HA enabled for routers that are part or a redundant network or VPCThis PR fixes the issue we were facing with crashed redundant routers not being picked up by the HA monitor due to an IF statement in the code.
* Redundant Routers are not the same as Haigh Available. Having a router HA is actually saying that the given router will be controlled by the High Availability monitor. Hence fix any problem we might face.
* pr/1222:
CLOUDSTACK-4374 - Adds HA capabilities to redundant routers
Signed-off-by: Remi Bergsma <github@remi.nl>
CLOUDSTACK-9086: ACS allows to create isolated networks with invalide gateway IP address - Fixed and Test cases added
Problem: There was no check for the network and broadcast IP addresses in the case where we provide the gateway and netmask while creating the isolated network. As a result the provided IP gets assigned to the eth0 interface of the VR.
Note: This is in continuation of PR #1125 which I closed.
* pr/1188:
CLOUDSTACK-9086: ACS allows to create isolated networks with invalide gateway IP address - Fixed and Test cases added
Signed-off-by: Remi Bergsma <github@remi.nl>
- Redundant Routers are not the same as Haigh Available.
Having a router HA is actually saying that the given router will be controlled by the High Availability monitor.
Hence fix any problem we might face.
- It is need and already allowed/used in the current implementation. For example, the Default [redundant] VPC offerings use
two LB providers. If we cannot create offerings with 2 LB providers, the whole internal loadbalancer implementation won't work
* 4.6:
CLOUDSTACK-9106 - Makes Enum name compliant with Java code conventions.
CLOUDSTACK-9106 - Adds a test to cover the changes in the applyVpnUsers() method
CLOUDSTACK-9106 - Makes the router commands call more consistent.
CLOUDSTACK-9106 - Enables private gateway tests on Redundant VPCs
CLOUDSTACK-9106 - Refactor the createPrivateNicProfileForGateway() method
CLOUDSTACK-9106 - Reduces the amount of iterations through the routers of a VPC
Add support for not (re)starting server after cloud-setup-management.
Closed PRs that will not be considered for merge:
This closes#1158
This closes#1097
- Checks the result of a call against the previous result. Either both are true or the method returns false.
- Do not thrown exceptions because some calls are not handling/rethrowing them. It would cause runtime problems.
- When doing a list.addAll(Arrays.asList(String[]{}) will cause problems when trying to cast the list.toArray() into an aray of String
It would only work if instead of calling addAll() I would pass it straight into the constructor:
e.g. List<String> l = new ArrayList(Arrays.asList(new String[]{});
Stirng [] s = (String[]) l.toArray();
But I did not like that implementation because it would require 2 arrays of string and combine them at the end.
- Use the router to retrieve the instance ID
- Check if the VPC is redundant in order to reuse the private gateway address.
- Brings the private gateways interfaces up.
- It was causing problems because Nics were expected to be plugged before they actually exist. Only in rVPC cases.
- Applies ACL items to routers only after the Pvt GW is setup.
CLOUDSTACK-9094: Multiple threads are being used to collect the statsCLOUDSTACK-9094: Multiple threads are being used to collect the stats from the same VR
Same thread is being intialised by two managers, VirtualNetworkApplianceManager and VpcVirtualNetworkApplianceManager
* pr/1140:
CLOUDSTACK-9094: Multiple threads are being used to collect the stats from the same VR
Signed-off-by: Rohit Yadav <rohit.yadav@shapeblue.com>
CLOUDSTACK-9047 rename enumsmake enums adhere to best practice naming conventions
* pr/1049:
CLOUDSTACK-9046 rename enums to adhere to naming conventions
CLOUDSTACK-9046 renamed enums in kvm plugin
CLOUDSTACK-9047 use 'State's only with context there are more types called 'State' (or to be called so but now 'state') So remove imports and prepend their enclosing class/context to them.
Signed-off-by: Daan Hoogland <daan@onecht.net>
[4.7] CLOUDSTACK-8958: add dedicated ips to domain (account for now)For now, we dedicate ip pool to account, however, other accounts in the same domain cannot fetch the ip from this ip pool.
By dedicating ip pool to domain, accounts in the domain can fetch the public ip from same ip pool.
* pr/1007:
CLOUDSTACK-8958: throw an exception if project account cannot be found
CLOUDSTACK-8958: add dedicated ips to domain (account for now)
Signed-off-by: Remi Bergsma <github@remi.nl>
* 4.6:
CLOUDSTACK-9053 security upgrade as per COLLECTIONS-580
CLOUDSTACK-9055: fix NPE in updating Redundant State of VPC networks
CLOUDSTACK-9057 remove old system vm upgrade code
CLOUDSTACK-8902 Restart Network fails in EIP/ELB zoneThe restart network was failing when using external loadbalencer. The failure was because of a number format exception. When BroadcastDomainType.getValue(guestConfig.getBroadcastUri() is executed this returns a string untagged. We were trying to parse this as long so there was a number pointer exception.
This happens only when the vlan uri is vlan://untagged. in other cases were there is a number instead of untagged (vlan tag) this used to succeed. Although we were trying to convert the number to long we were not really using it. we were converting the number to long and then back to string when creating the IpAddressTo. so I removed this unnecessary conversion in this case for fixing the issue at hand.
I did a manual restart of the network and checked for this number format exception in a EIP/ELB setup.
* pr/898:
CLOUDSTACK-89027 Restart Network fails in EIP/ELB zone
Signed-off-by: Remi Bergsma <github@remi.nl>
CLOUDSTACK-9016 Fail to create VM instance within VPCbug link https://issues.apache.org/jira/browse/CLOUDSTACK-9016.
CS doe not allocate the ip of the form x.x.x.1 to a guest VM. We seem to incorrectly assume that the first ip in the subnet belongs to the gateway.
* pr/1020:
CLOUDSTACK-9016: Deploy vm with gateway ip address in VPC
CLOUDSTACK-9016 Fail to create VM instance within VPC
Signed-off-by: Remi Bergsma <github@remi.nl>
CLOUDSTACK-8940: Wrong value is inserted into nics table netmask field when creating a VM - Fixed
Problem: When creating a VM in shared network with no service, the value of netmask is added in the table in the CIDR format unlike other cases where it is added as normal string in the format xxx.xxx.xxx.xxx. The netmask column in the nics table has a length of 15 chars which gets violated if the CIDR exceeds it(Max CIDR length can be 18).
Fix: Before storing the netmask convert from CIDR to native format.
* pr/916:
CLOUDSTACK-8940: Wrong value is inserted into nics table netmask field when creating a VM - Fixed
Signed-off-by: Remi Bergsma <github@remi.nl>