Preparatory data-model changes for NVMe-TCP support on the adaptive
storage framework. No behaviour change for existing Fibre Channel
users - the extra enum value, field, and getter/setter are only
exercised by callers that explicitly use them.
ProviderVolume.AddressType gains a NVMETCP value alongside FIBERWWN,
so adapters can declare that a volume is addressed by an NVMe EUI-128
(NGUID) rather than a SCSI WWN.
FlashArrayVolume.getAddress() produces the NGUID layout expected by
the Linux kernel for a FlashArray NVMe namespace:
00 + serial[0:14] + 24a937 (Pure 6-hex OUI) + serial[14:24]
which matches the /dev/disk/by-id/nvme-eui.<id> symlink emitted by
udev. Fibre Channel callers (addressType != NVMETCP) still get the
existing 6 + 24a9370 + serial form.
FlashArrayConnection gains a nsid field to carry the namespace id the
FlashArray REST API attaches to host-group-scoped NVMe connections,
when it is present.
* initial attempt at network.loadbalancer.haproxy.idle.timeout implementation
* implement test cases
* move idleTimeout configuration test to its own test case
`cursor` field when more pages are available. The previous implementation only
fetched the first page and ignored pagination.
This change updates the list retrieval flow to:
- follow the `cursor` chain until no further pages exist
- accumulate items from all pages
- return a single merged result to the caller
This ensures that list operations return the complete dataset rather than just
the first page.
Co-authored-by: Andrey Volchkov <avolchkov@playtika.com>
* kvm: fix wrong CheckVirtualMachineAnswer when vm does not exist
* kvm: add LibvirtCheckVirtualMachineCommandWrapperTest
Co-authored-by: dahn <daan.hoogland@gmail.com>
* Fix domain parsing for GPU
* Add Display controller to GPU class check
this adds support for the amd instinct mi2xx accelorator crards in the discovery script.
Co-authored-by: Piet Braat <piet@phiea.nl>
Fixes an issue in NsxResource.executeRequest where Network.Service
comparison failed when DeleteNsxNatRuleCommand was executed in a
different process. Due to serialization/deserialization, the
deserialized Network.Service instance was not equal to the static
instances Network.Service.StaticNat and Network.Service.PortForwarding,
causing the comparison to always return false.
Co-authored-by: Andrey Volchkov <avolchkov@playtika.com>
* Fix NPE in NASBackupProvider when no running KVM host is available
ResourceManager.findOneRandomRunningHostByHypervisor() can return null
when no KVM host in the zone has status=Up (e.g. during management
server startup, brief agent disconnections, or host state transitions).
NASBackupProvider.syncBackupStorageStats() and deleteBackup() call
host.getId() without a null check, causing a NullPointerException that
crashes the entire BackupSyncTask background job every sync interval.
This adds null checks in both methods:
- syncBackupStorageStats: log a warning and return early
- deleteBackup: throw CloudRuntimeException with a descriptive message
* PowerFlex/ScaleIO client initialization, authentication and command execution improvements
* Migrate VM with volume not supported yet for PowerFlex/ScaleIO
* review changes