- pool allocation checks for both root and data disks
- NPE checks to not add null object in collection or try to migrate null VM
- HA work tries need to increment and be given up when max retries are crossed
- VM creation should check IP address format for IPv4 and IPv6
- If userdata is not supported by a network, then fail early if userdata, ssh key,
or password enabled template is passed/used
Signed-off-by: Rohit Yadav <rohit.yadav@shapeblue.com>
(cherry picked from commit 24435dd6bc)
Signed-off-by: Rohit Yadav <rohit.yadav@shapeblue.com>
1. provide compatibility with the Big Cloud Fabric (BCF) controller
L2 Connectivity Service in both VPC and non-VPC modes
2. virtual network terminology updates: VNS --> BCF_SEGMENT
3. uses HTTPS with trust-always certificate handling
4. topology sync support with BCF controller
5. support multiple (two) BCF controllers with HA
6. support VM migration
7. support Firewall, Static NAT, and Source NAT with NAT enabled option
8. add VifDriver for Indigo Virtual Switch (IVS)
This closes#151
Signed-off-by: Rohit Yadav <rohit.yadav@shapeblue.com>
- With the changes added by the rVPC work, the bump priority became deprecated.
This commit includes a refactor to get it removed from the following resources:
* Java classes
* domain_router table - removing the is_priority_bumpup column
* Fixing unit tests
All changes were tested with:
XenServer 6.2 running under our VMWare zone
CloudStack Management Server running on MacBook Pro
MySql running on MackBook Pro
Storage Type: Local
Customise the messages showed during VPC restart based on redundancy
Do not show "Make Redundant" option if VPC is already redundant
Show on VPC details if a VPC is redundant
Fix the router state. do not show UNKNOW, but MASTER or BACKUP depending on the type of router
Implement the virtual_router_id to be passed as a boot parameter to the router
- it is needed for the keepalived configuration
Fix: RTNETLINK errors
- Management Server health check trying to create already existing interface
- Changes on update_config.py, cs_guestnetwork.py, merger.py
Fix: replace RRouTER_LOG in the CsRedundant.py per log file location
Fix: Guest Net address association during Router restart
- Changes on NicProfileHelper, NicProfileHelperImpl
Fix: aggregationExecution() method on VirtualNetworkApplianceManagerImpl
- Do not send an AggregationControlCommand to a non-configured router
Some classes have been formatted.
Fixing assign IPv4 on GuestNetworkGuru.java
Fixing getRouters() on VpcVirtualRouterElement.java
Fixing Fixing paths on keepalived.conf.templ
Refactor on the other files
* removed the "is redundant" flag form the addVpcRouterToGuestNetwork() method
* removed the "is redundant" flag from the removeVpcRouterFromGuestNetwork() method
* changed the path of the master.py file in the keepalived.conf.temp file
* the call to routerDao.addRouterToGuestNetwork() in the VpcRouterDeploymentDefinition is not needed. That step will be performed once a VM is created
- In addition, when restarting a VPC the routers will have the guest net configured, if any exists.
* Pushing the POM.xml as well, to use the old Jetty for now. Could not fix the logging problem. Will replace the POM with master version after VPC is done.
Fixing Finalize methods in the VpcVirtualNetworkApplianceManager
Making use ot eh RouterControlHelper instead of duplicating methods in the VirtualNetworkApplianceManager
[witp] - redundant vpc virtual routers have the same mac address, have to fix that.
There were more places were the amount of routers is checked.
Not throwing exception when routers > 1
[wip] - we need to refactor VpcViortualRouterElement in order to cope with methods returning true only for the sake of it.