Rohit Yadav 07564469e9 CLOUDSTACK-9299: Out-of-band Management for CloudStack
Support access to a host’s out-of-band management interface (e.g. IPMI, iLO,
DRAC, etc.) to manage host power operations (on/off etc.) and querying current
power state in CloudStack.

Given the wide range of out-of-band management interfaces such as iLO and iDRA,
the service implementation allows for development of separate drivers as plugins.
This feature comes with a ipmitool based driver that uses the
ipmitool (http://linux.die.net/man/1/ipmitool) to communicate with any
out-of-band management interface that support IPMI 2.0.

This feature allows following common use-cases:
- Restarting stalled/failed hosts
- Powering off under-utilised hosts
- Powering on hosts for provisioning or to increase capacity
- Allowing system administrators to see the current power state of the host

For testing this feature `ipmisim` can be used:
https://pypi.python.org/pypi/ipmisim

FS:
https://cwiki.apache.org/confluence/display/CLOUDSTACK/Out-of-band+Management+for+CloudStack

Signed-off-by: Rohit Yadav <rohit.yadav@shapeblue.com>
2016-05-12 11:05:40 +05:30
..
resources/META-INF/cloudstack CLOUDSTACK-9299: Out-of-band Management for CloudStack 2016-05-12 11:05:40 +05:30
src CLOUDSTACK-9299: Out-of-band Management for CloudStack 2016-05-12 11:05:40 +05:30
test/com/cloud/upgrade/dao CLOUDSTACK-6594: Improve the logging in the util functions utilized by db upgrades currently. If the exception is to be ignored, dont log the stack trace and also dont log it in warn. Making them debug just to be little verbose during upgrade scenario. 2014-07-31 16:36:33 -07:00
pom.xml Updating pom.xml version numbers for release 4.9.0-SNAPSHOT 2016-01-26 15:12:20 +01:00