This fixes the agreed upon url on download.cloudstack.org in various
sql files and misc scripts.
Signed-off-by: Rohit Yadav <rohit.yadav@shapeblue.com>
- commented some occurences of cloud.com as being harmless
* examples
* identifiers (internal)
- changed the URL for vhd-util download
- changed comments from 'cloud.com' to 'Apache CloudStack'
* 4.9:
CLOUDSTACK-9876: Removed test test_01_test_vm_volume_snapshot as we no longer have that restriction and now after fix for CLOUDSTACK-8663 we allow VM and volume snapshots to exist together
[master/4.10+] CLOUDSTACK-9462: Support for Ubuntu 14.04/16.04 with tomcat6/tomcat7This extends work from @ustcweizhou from https://github.com/apache/cloudstack/pull/1950 by fixing some build issues to make this work with Ubuntu 14.04 and 16.04.
This closes#1950
* pr/2033:
CLOUDSTACK-9462: Build packages on Ubuntu 14.04/16.04 and support tomcat6/tomcat7
Signed-off-by: Rajani Karuturi <rajani.karuturi@accelerite.com>
[4.10-blocker] Fix error in restart network in 4.10.0.0 RCThe PR fixes the error in restart network:
2017-04-04 10:27:39,217 DEBUG [c.c.n.r.NetworkHelperImpl] (API-Job-Executor-2:ctx-08904854 job-29417 ctx-3405d3f2) (logid:19bbd6e6) Router requires upgrade. Unable to send command to router:9784, router template version : Cloudstack Release 4.10.0 Wed Feb 15 05:42:18 UTC 2017, minimal required version : 4.10.0.0
It works after changing minreq.sysvmtemplate.version from 4.10.0.0 to 4.10.0
* pr/2025:
Fix error in restart network in 4.10.0.0 RC
Signed-off-by: Rajani Karuturi <rajani.karuturi@accelerite.com>
[dvswitch blocker] CLOUDSTACK-9591: Fix systemvmtemplate to not include network detailsThis removes nic/network specific details while exporting the systemvmtemplate for vmware (ova file). Having this causes the ssvms to not deploy in dvswitch-based vmware environments that have no vswitch portgroups (dummy etc). Tested this on a local Trillian env.
* pr/2022:
CLOUDSTACK-9591: Fix guest VM ovf xml to remove network nodes
CLOUDSTACK-9591: Fix systemvmtemplate to not include network details
Signed-off-by: Rajani Karuturi <rajani.karuturi@accelerite.com>
CLOUDSTACK-9783: corrected the version number in metrics pommaster is broken after fwd-merging metrics PR #1944 from 4.9
This is due to the incorrect parent version number in the metrics pom.
Corrected the same to reflect master version number.
* pr/2032:
CLOUDSTACK-9783: corrected the version number in metrics pom
Signed-off-by: Rajani Karuturi <rajani.karuturi@accelerite.com>
master is broken after fwd-merging metrics PR #1944 from 4.9
This is due to the incorrect parent version number in the metrics pom.
Corrected the same to reflect master version number.
CLOUDSTACK-9720: [VMware] template_spool_ref table is not getting updated with correct template physical size in template_size column.Updated the template_spool_ref table with the correct template (VMware - OVA file) size.
* pr/1880:
CLOUDSTACK-9720: [VMware] template_spool_ref table is not getting updated with correct template physical size in template_size column.
Signed-off-by: Rajani Karuturi <rajani.karuturi@accelerite.com>
CLOUDSTACK-9783: Improve metrics view performanceThis improves the metrics view feature by improving the rendering performance
of metrics view tables, by re-implementing the logic at the backend and data
served via APIs. In large environments, the older implementation would
make several API calls that increases both network and database load.
List of APIs introduced for improving the performance that re-implement the frontend logic at backend:
listClustersMetrics
listHostsMetrics
listInfrastructure
listStoragePoolsMetrics
listVMsMetrics
listVolumesMetrics
listZonesMetrics
Pinging for review - @abhinandanprateek @DaanHoogland @borisstoyanov @karuturi @rashmidixit
Marvin test results:
=== TestName: test_list_clusters_metrics | Status : SUCCESS ===
=== TestName: test_list_hosts_metrics | Status : SUCCESS ===
=== TestName: test_list_infrastructure_metrics | Status : SUCCESS ===
=== TestName: test_list_pstorage_metrics | Status : SUCCESS ===
=== TestName: test_list_vms_metrics | Status : SUCCESS ===
=== TestName: test_list_volumes_metrics | Status : SUCCESS ===
=== TestName: test_list_zones_metrics | Status : SUCCESS ===
* pr/1944:
CLOUDSTACK-9783: Improve metrics view performance
Signed-off-by: Rajani Karuturi <rajani.karuturi@accelerite.com>
CLOUDSTACK-9854: Fix test_primary_storage test failure due to live migrationFix for test_primary_storage integration tests on simulator.
When finding storage pool migration options for volume on running vm, API returns None as hypervisor doesn't support live migration.
````
2017-03-28 06:07:55,958 - DEBUG - ========Sending GET Cmd : findStoragePoolsForMigration=======
2017-03-28 06:07:55,977 - DEBUG - Response : None
2017-03-28 06:07:55,983 - CRITICAL - EXCEPTION: test_03_migration_options_storage_tags: ['Traceback (most recent call last):\n', ' File "/opt/python/2.7.12/lib/python2.7/unittest/case.py", line 329, in run\n testMethod()\n', ' File "/home/travis/.local/lib/python2.7/site-packages/marvin/lib/decoratorGenerators.py", line 30, in test_wrapper\n return test(self, *args, **kwargs)\n', ' File "/home/travis/build/apache/cloudstack/test/integration/smoke/test_primary_storage.py", line 547, in test_03_migration_options_storage_tags\n pools_suitable = filter(lambda p : p.suitableformigration, pools_response)\n', "TypeError: 'NoneType' object is not iterable\n"]
````
So we simply stop vm before sending findStoragePoolsForMigration command
* pr/2021:
CLOUDSTACK-9854: Fix test_primary_storage test failure due to live migration
Signed-off-by: Rajani Karuturi <rajani.karuturi@accelerite.com>
This removes network details from the guest VM template OVF xml before deploying
a VM which would fail in case of dvswitch-based vmware environment with no
dummy/existing vswitch.
Signed-off-by: Rohit Yadav <rohit.yadav@shapeblue.com>
This removes nic/network specific details while exporting the systemvmtemplate
for vmware (ova file). Having this causes the ssvms to not deploy in
dvswitch-based vmware environments that have no vswitch portgroups (dummy etc).
Tested this on a local Trillian env.
Signed-off-by: Rohit Yadav <rohit.yadav@shapeblue.com>
Fix for test_snapshots.py using nfs2 instead of nfs templateFix for marvin test failure introduced in #1847
Cc: @borisstoyanov @rhtyd @karuturi
* pr/1961:
Fix for test failure
Fix for test_snapshots.py using nfs2 instead of nfs template
Signed-off-by: Rajani Karuturi <rajani.karuturi@accelerite.com>
CLOUDSTACK-9811: fix duplicated nics on VR caused by nic name p<slot_number>p<port_number>
* pr/2011:
CLOUDSTACK-9811: fix duplicated nics on VR caused by nic name p<slot_number>p<port_number>
Signed-off-by: Rajani Karuturi <rajani.karuturi@accelerite.com>
CLOUDSTACK-9811: fixed an issue if the dev is not in the databagDefend against the specified dev not being in the databag.
* pr/2003:
changed the order fix to be closer to the original code
CLOUDSTACK-9811: fixed an issue if the dev is not in the databag
Signed-off-by: Rajani Karuturi <rajani.karuturi@accelerite.com>
Bug-ID: CLOUDSTACK-8880: calculate free memory on host before deploying Vm. free memory = total memory - (all vm memory)With memory over-provisioning set to 1, when mgmt server starts VMs in parallel on one host, then the memory allocated on that kvm can be larger than the actual physcial memory of the kvm host.
Fixed by checking free memory on host before starting Vm.
Added test case to check memory usage on Host.
Verified Vm deploy on Host with enough capacity and also without capacity
* pr/847:
Bug-ID: CLOUDSTACK-8880: calculate free memory on host before deploying Vm. free memory = total memory - (all vm memory)
Signed-off-by: Rajani Karuturi <rajani.karuturi@accelerite.com>
CLOUDSTACK-9794: Unable to attach more than 14 devices to a VMUpdated hardcoded value with max data volumes limit from hypervisor capabilities.
* pr/1953:
CLOUDSTACK-9794: Unable to attach more than 14 devices to a VM
Signed-off-by: Rajani Karuturi <rajani.karuturi@accelerite.com>
CLOUDSTACK-5806: add presetup to storage types that support over provisioning
Ideally this should be configurable via global settings
* pr/1958:
CLOUDSTACK-5806: add presetup to storage types that support over provisioning Ideally this should be configurable via global settings
Signed-off-by: Rajani Karuturi <rajani.karuturi@accelerite.com>
CLOUDSTACK-9698 [VMware] Make hardcorded wait timeout for NIC adapter hotplug as configurableJira
===
CLOUDSTACK-9698 [VMware] Make hardcoded wait timeout for NIC adapter hotplug as configurable
Description
=========
Currently ACS waits for 15 seconds (hard coded) for hot-plugged NIC in VR running on VMware to get detected by guest OS.
The time taken to detect hot plugged NIC in guest OS depends on type of VMware NIC adapter like (E1000, VMXNET3, E1000e etc.)
and guest OS itself. In uncommon scenarios the NIC detection may take longer time than 15 seconds,
in such cases NIC hotplug would be treated as failure which results in VPC tier configuration failure.
Alternatively making the wait timeout for NIC adapter hotplug as configurable will be helpful for admins in such scenarios. This is specific to VR running over VMware hypervisor.
Also in future if VMware introduces new NIC adapter types which may take time to get detected by guest OS, it is good to have flexibility of
configuring the wait timeout as fallback mechanism in such scenarios.
Fix
===
Introduce new configuration parameter (via ConfigKey) "vmware.nic.hotplug.wait.timeout" which is "Wait timeout (milli seconds) for hot plugged NIC of VM to be detected by guest OS." as fallback instead of hard coded timeout, to ensure flexibility for admins given the listed scenarios above.
Signed-off-by: Sateesh Chodapuneedi <sateesh.chodapuneedi@accelerite.com>
* pr/1861:
CLOUDSTACK-9698 Make the wait timeout for NIC adapter hotplug as configurable
Signed-off-by: Rajani Karuturi <rajani.karuturi@accelerite.com>
* 4.9:
moved logrotate from cron.daily to cron.hourly for vpcrouter in cloud-early-config
CLOUDSTACK-9569: propagate global configuration router.aggregation.command.each.timeout to KVM agent
[4.9] CLOUDSTACK-9569: propagate global configuration router.aggregation.command.each.timeout to KVM agentThe router.aggregation.command.each.timeout in global configuration is only applied on new created KVM host.
For existing KVM host, changing the value will not be effective.
We need to propagate the configuration to existing host when cloudstack-agent is connected.
* pr/1856:
CLOUDSTACK-9569: propagate global configuration router.aggregation.command.each.timeout to KVM agent
Signed-off-by: Rajani Karuturi <rajani.karuturi@accelerite.com>