* Refactoring Allocator classes
* Break into smaller methods random and firfit allocators.
* Added unit tests for random and firstfit allocators
* Move random allocator from cloud-plugins to cloud-server
* Add BaseAllocator abstract class for duplicate code
* Add missing license
* Add missing license to unit test file
* Remove host allocator random dependency
* Change exception message on smoke tests
* Remove conditional as it was never actually reached in the original flow
* Fix tests
* Fix flipped parameters
* Fix NPE while listing hosts for migration when suitableHosts is null
* Remove unnecessary stubbings
* Fix checkstyle
* Remove unnecessary file
* Rename exception error messages
* Apply suggestions from code review
Co-authored-by: Fabricio Duarte <fabricio.duarte.jr@gmail.com>
* Rename UserVmDetailVO references to VMInstanceDetailVO
* Remove unused imports
* Add new line at EOF
* Remove unnecessary random allocator pom
* Fix GPU allocation mistake
* Fix failing tests
---------
Co-authored-by: Fabricio Duarte <fabricio.duarte@scclouds.com.br>
Co-authored-by: Fabricio Duarte <fabricio.duarte.jr@gmail.com>
* Linstor: fix create volume from snapshot on primary storage
When creating a volume from a snapshot on Linstor primary storage
(with lin.backup.snapshots=false), the operation fails with:
"Only the following image types are currently supported: VHD, OVA,
QCOW2, RAW (for PowerFlex and FiberChannel)"
Root cause: the Linstor driver does not handle SNAPSHOT -> VOLUME in
its canCopy()/copyAsync() methods. This causes DataMotionServiceImpl
to fall through to StorageSystemDataMotionStrategy (selected because
Linstor advertises STORAGE_SYSTEM_SNAPSHOT=true). That strategy's
verifyFormatWithPoolType() rejects RAW format for Linstor pools,
since RAW is only allowed for PowerFlex and FiberChannel.
Additionally, VolumeOrchestrator.createVolumeFromSnapshot() attempts
to back up the snapshot to secondary storage when the storage plugin
does not advertise CAN_CREATE_TEMPLATE_FROM_SNAPSHOT. This backup
fails because the snapshot only exists on Linstor primary storage.
Fix:
- Add CAN_CREATE_TEMPLATE_FROM_SNAPSHOT capability so the
orchestrator skips the backup-to-secondary path
- Add canCopySnapshotToVolumeCond() to match SNAPSHOT -> VOLUME
when both are on the same Linstor primary store
- Wire it into canCopy() to intercept at DataMotionServiceImpl
before strategy selection, bypassing StorageSystemDataMotionStrategy
- Implement copySnapshotToVolume() which delegates to the existing
createResourceFromSnapshot() for native Linstor snapshot restore
This follows the same pattern used by the StorPool plugin, which
handles SNAPSHOT -> VOLUME directly in its driver rather than going
through StorageSystemDataMotionStrategy.
Tested on CloudStack 4.22 with Linstor LVM_THIN storage, creating
a volume from a 1TB CNPG Postgres database snapshot. Volume creates
successfully with correct path and deletes cleanly.
* Let CloudRuntimeException propagate from copySnapshotToVolume
Remove try/catch in copySnapshotToVolume so that CloudRuntimeException
from createResourceFromSnapshot propagates to the caller, ensuring
CloudStack properly notices and reports the failure.
* Fix CAN_CREATE_TEMPLATE_FROM_SNAPSHOT breaking template creation
Setting CAN_CREATE_TEMPLATE_FROM_SNAPSHOT unconditionally to true
caused createTemplate from snapshot to take the StorPool-specific
code path in TemplateManagerImpl, which sends a CopyCommand to a
system VM that Linstor cannot handle.
Fix: make CAN_CREATE_TEMPLATE_FROM_SNAPSHOT conditional on the same
flag as STORAGE_SYSTEM_SNAPSHOT (!BackupSnapshots). When snapshots
are backed up to secondary (the default), the old template creation
flow works. When snapshots stay on primary, the direct path is used.
Also fix checkstyle: remove unused DataObject import in test.
Co-authored-by: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
* Fix bulk power state query missing VM lifecycle state field
The IdsPowerStateSelectSearch partial select did not include the VM
lifecycle state, causing isPowerStateInSyncWithInstanceState to always
return true when state was null. This prevented retry of failed
StopCommands on subsequent ping cycles.
* Add defensive check for instance host ID to prevent NPE
Co-authored-by: Sachin R Doddaguni <s_rudrappadoddagu@apple.com>
Co-authored-by: nvazquez <nicovazquez90@gmail.com>
* Move logs for values of the migration settings out of the loop
* Apply suggestions from code review
Co-authored-by: Suresh Kumar Anaparti <sureshkumar.anaparti@gmail.com>
---------
Co-authored-by: Suresh Kumar Anaparti <sureshkumar.anaparti@gmail.com>
Fixes an issue in NsxResource.executeRequest where Network.Service
comparison failed when DeleteNsxNatRuleCommand was executed in a
different process. Due to serialization/deserialization, the
deserialized Network.Service instance was not equal to the static
instances Network.Service.StaticNat and Network.Service.PortForwarding,
causing the comparison to always return false.
Co-authored-by: Andrey Volchkov <avolchkov@playtika.com>
(cherry picked from commit 30dd234b00)
* Fix static routes to be added to PBR tables in VPC routers
Static routes were only being added to the main routing table, but
policy-based routing (PBR) is active on VPC routers. This caused
traffic coming in from specific interfaces to not find the static
routes, as they use interface-specific routing tables (Table_ethX).
This fix:
- Adds a helper method to find which interface a gateway belongs to
by matching the gateway IP against configured interface subnets
- Modifies route add/delete operations to update both the main table
and the appropriate interface-specific PBR table
- Uses existing CsAddress databag metadata to avoid OS queries
- Handles both add and revoke operations for proper cleanup
- Adds comprehensive logging for troubleshooting
Fixes#12857
* Add iptables FORWARD rules for nexthop-based static routes
When static routes use nexthop (gateway) instead of referencing a
private gateway's public IP, the iptables FORWARD rules were not
being generated. This caused traffic to be dropped by ACLs.
This fix:
- Adds a shared helper CsHelper.find_device_for_gateway() to determine
which interface a gateway belongs to by checking subnet membership
- Updates CsStaticRoutes to use the shared helper instead of duplicating
the device-finding logic
- Modifies CsAddress firewall rule generation to handle both old-style
(ip_address-based) and new-style (nexthop-based) static routes
- Generates the required FORWARD and PREROUTING rules for nexthop routes:
* -A PREROUTING -s <network> ! -d <interface_ip>/32 -i <dev> -j ACL_OUTBOUND_<dev>
* -A FORWARD -d <network> -o <dev> -j ACL_INBOUND_<dev>
* -A FORWARD -d <network> -o <dev> -m state --state RELATED,ESTABLISHED -j ACCEPT
Fixes the second part of #12857
* network matching grep fix, don't let 1.2.3.4/32 match 11.2.3.4/32
* initial attempt at network.loadbalancer.haproxy.idle.timeout implementation
* implement test cases
* move idleTimeout configuration test to its own test case
`cursor` field when more pages are available. The previous implementation only
fetched the first page and ignored pagination.
This change updates the list retrieval flow to:
- follow the `cursor` chain until no further pages exist
- accumulate items from all pages
- return a single merged result to the caller
This ensures that list operations return the complete dataset rather than just
the first page.
Co-authored-by: Andrey Volchkov <avolchkov@playtika.com>
* Fix VPC restart with multi-CIDR networks: handle comma-separated CIDR in NetworkVO.equals()
When a network has multiple CIDRs (e.g. '192.168.2.0/24,160.0.0.0/24'),
NetworkVO.equals() passes the raw comma-separated string to
NetUtils.isNetworkAWithinNetworkB() which expects a single CIDR,
causing 'cidr is not formatted correctly' error during VPC restart
with cleanup=true.
Extract only the first CIDR value before passing to NetUtils.
* Fix root cause: skip CIDR/gateway updates for Public traffic type networks
addCidrAndGatewayForIpv4/Ipv6 (introduced by PR #11249) was called for all
network types without checking if the network is Public. This caused
comma-separated CIDRs to be stored on Public networks, which then triggered
'cidr is not formatted correctly' errors during VPC restart.
Add TrafficType.Public guard in both the VLAN creation (addCidr) and
VLAN deletion (removeCidr) paths in ConfigurationManagerImpl.
* Sanitize legacy network-level addressing fields for Public networks
---------
Co-authored-by: dahn <daan@onecht.net>
Changes to check resource limits with reservations for the following
resource types:
- backup
- backup_storage
- bnucket
- object_storage
Signed-off-by: Abhishek Kumar <abhishek.mrt22@gmail.com>